TECHNICAL DATA
DIMENSIONS:
• assembly hole size: 142+1mm X 237+1mm
• assembly depth including terminals: 55mm
• outside dimensions: 265x152
WEIGHT:
• 1250 g (RECORDER)
• 800 g (TRANSFORMER)
POWER SUPPLY:
• ~24V(AC), 220-24V TRANSFORMER INCLUDED IN THE SET
STRUCTURE:
• SINGLE ELEMENT, “FRONT PANEL”-TYPE
PROTECTION CLASS: (ACCORDING TO IEC 529)
• from terminal side: IP 20
• from front side: IP 65
HUMIDITY:
• 0..75 % (OF RELATIVE HUMIDITY)
TEMPERATURE:
• ambient: -20..+70 °C
• working: 0..+60 °C
OUTPUTS:
• max 12 RELAY OUTPUTS 250V,
TOTAL
CURRENT INTENSITY OF CONNECTED RELAYS: Icmax=4A
• 4 TRANSISTOR OUTPUTS, Iomax=100mA (optionally)
INPUTS:
• 8 MEASUREMENT CHANNELS WITH INPUT
- PT-100 - MEASUREMENT RANGE FROM -100.0°C TO +400.0°C,
RESOLUTION (ACCURACY) 0.1°C
- CURRENT SIGNAL: 0..20 mA , 4..20 mA (RANGE: 3 DIGITS)
• BINARY CONTROL INPUT: 0-220V AC (0-24 V AC)
DIGITAL COMMUNICATION:
• SERIAL PORT
1xRS-232 (PRINTER)
1xRS-485 (MASTER COMPUTER)
RECORDING MEMORY:
• 2000 samples / channel for RAM memory = 32KB (STANDARD)